How Does Water Electrolysis Work? Alkaline, PEM, and Solid Oxide Electrolyzers Explained

A chemical-engineering guide to water electrolysis: alkaline, PEM and solid-oxide electrode reactions, ion transport, voltage losses, Faraday’s law, energy use, plant design and worked calculations.

Original RENEWIOSITY educational hero illustration introducing alkaline, proton exchange membrane (PEM), and high-temperature solid oxide electrolysis for green hydrogen production. The facility is conceptual and not an equipment specification.

Water electrolysis uses direct-current electrical energy to split water into hydrogen and oxygen. The reaction is simple to balance, but practical electrolyzer performance depends on electrode kinetics, ionic conduction, gas separation, operating temperature, pressure, current density, water quality, and the design of the balance of plant. This lesson explains how alkaline, proton-exchange-membrane (PEM), and solid-oxide electrolysis work—and why they are not interchangeable engineering solutions.

This is the second of three foundational lessons in RENEWIOSITY's Green Hydrogen learning path for advanced undergraduate Chemical Engineering students. Read What Is Green Hydrogen? first for hydrogen production pathways and basic material balances. Green Hydrogen Production Calculations develops full plant sizing, performance, and energy calculations.

Learning objectives

  • Identify the anode, cathode, electrolyte, separator, DC power supply, and auxiliary systems in an electrolyzer.
  • Write correctly balanced alkaline, PEM, and oxygen-ion-conducting solid-oxide half-reactions.
  • Explain why hydroxide, protons, or oxide ions migrate through different electrolytes.
  • Distinguish Gibbs free energy, reaction enthalpy, reversible voltage, and thermoneutral voltage.
  • Interpret a polarization curve and quantify activation, ohmic, and mass-transport voltage losses.
  • Apply Faraday’s law to estimate hydrogen production and relate cell current, area, current density, and stack power.
  • Compare commercial alkaline and PEM electrolysis with high-temperature solid-oxide and emerging AEM systems.
  • Recognize practical constraints from heat integration, gas crossover, water treatment, stack degradation, and hydrogen safety.

1. What happens inside a water electrolyzer?

An electrolyzer contains two electrodes: the cathode, where reduction produces hydrogen, and the anode, where oxidation produces oxygen. A DC power supply drives electrons through an external circuit. An electrolyte conducts ions internally while helping separate product gases. Water and/or steam is supplied at the electrode appropriate to the technology. Hydrogen and oxygen streams are then conditioned, monitored, and separated from any entrained water.

A single electrochemical cell has a voltage typically above the thermodynamic reversible voltage under hydrogen-producing load. Multiple cells are connected electrically in series to create a stack; the same current passes through each series cell, and the cell voltages add. Industrial facilities add rectifiers, pumps, separators, cooling or heating loops, dryers, gas-quality monitoring, pressure regulation, and safety systems. A stack rating is not necessarily the same as the AC power demand of the entire plant.

Overall water-splitting reaction
2\,\mathrm{H_2O}\rightarrow 2\,\mathrm{H_2}+\mathrm{O_2}

This stoichiometric relation applies to all three technologies. The physical state of the water feed depends on temperature and process design.

Three-panel diagram showing hydroxide transport in alkaline electrolysis, proton transport in PEM electrolysis and oxide-ion transport in SOEC.

2. Electrode polarity and the meaning of oxidation

In an electrolyzer, the anode is positive relative to the cathode and hosts oxidation; the cathode is negative and hosts reduction. These oxidation/reduction definitions do not change between electrolyzers and fuel cells, although the external electrical operating mode and electrode polarities do. Anode and cathode are defined by reactions, not by a fixed plus or minus sign in every electrochemical device.

Two electrons are transferred through the external circuit for each molecule of H₂ produced. This provides the fundamental link between current, operating time, and hydrogen production. In a real plant, some charge may contribute to side processes or losses, represented by Faradaic efficiency.

3. Alkaline water electrolysis (AWE)

Conventional alkaline electrolyzers typically use aqueous potassium hydroxide (KOH) or sodium hydroxide (NaOH), with a diaphragm or separator between electrodes. At the cathode, water is reduced to H₂ and hydroxide ions. The hydroxide ions migrate through the alkaline electrolyte toward the anode, where O₂ forms. Nickel-based electrode materials and established industrial construction are common advantages; electrolyte handling, gas crossover at low loads, and some operating constraints require attention.

Alkaline cathode: hydrogen evolution
4\,\mathrm{H_2O}+4e^-\rightarrow 2\,\mathrm{H_2}+4\,\mathrm{OH^-}

Hydrogen evolves at the cathode; hydroxide ions are formed there.

Alkaline anode: oxygen evolution
4\,\mathrm{OH^-}\rightarrow \mathrm{O_2}+2\,\mathrm{H_2O}+4e^-

Hydroxide ions travel toward the anode, where oxygen is generated and electrons are released.

Adding the half-reactions cancels four electrons and four hydroxide ions, giving the net water-splitting equation. Because gas products must remain separated, diaphragm performance and gas monitoring matter especially during changing load or pressure differentials. Actual turndown, start-up, pressure, and current-density limits depend on the particular commercial design, not simply the word “alkaline.”

4. Proton exchange membrane electrolysis (PEMWE)

A PEM electrolyzer uses a solid proton-conducting polymer membrane. Water is typically supplied on the oxygen-evolving anode side. The anode reaction creates O₂, H⁺, and electrons. Protons cross the membrane to the cathode, where they combine with externally supplied electrons to produce H₂. The membrane acts as an ionic conductor and gas separator; suitable hydration and water purity are essential.

PEM anode: oxygen evolution
2\,\mathrm{H_2O}\rightarrow \mathrm{O_2}+4\,\mathrm{H^+}+4e^-

The oxygen-evolving anode produces protons and electrons as it oxidizes water.

PEM cathode: hydrogen evolution
4\,\mathrm{H^+}+4e^-\rightarrow 2\,\mathrm{H_2}

Protons cross the membrane toward the cathode, where hydrogen gas is formed.

PEM systems can offer compact stacks, high current density, differential-pressure operation in appropriate designs, and fast response to variable renewable electricity. Trade-offs include stringent feedwater purity, membrane durability, and reliance on corrosion-resistant materials and often platinum-group-metal catalysts—particularly for the oxygen-evolution anode. Actual equipment choices vary among manufacturers.

Do not confuse PEM water electrolysis with a PEM fuel cell: both may use a proton-conducting membrane, but the net reaction and direction of electrical energy conversion are opposite. For electrolyzers, electricity is consumed to make hydrogen.

5. Solid oxide electrolysis cells (SOECs)

In the common oxygen-ion-conducting SOEC, steam enters a high-temperature hydrogen electrode. Water vapor accepts electrons to form H₂ and oxide ions (O²⁻). The oxide ions cross a dense ceramic electrolyte to the oxygen electrode, where oxygen gas is released. SOECs typically operate at several hundred degrees Celsius, often roughly 650–850°C depending on materials and design. The terminology “fuel electrode” and “oxygen electrode” is also common in reversible solid-oxide systems.

SOEC steam-electrode reaction
2\,\mathrm{H_2O(g)}+4e^-\rightarrow 2\,\mathrm{H_2(g)}+2\,\mathrm{O^{2-}}

Steam is reduced at the hydrogen-producing electrode; oxide ions are generated.

SOEC oxygen-electrode reaction
2\,\mathrm{O^{2-}}\rightarrow \mathrm{O_2(g)}+4e^-

Oxide ions move through the solid ceramic electrolyte to the oxygen-evolving electrode.

High-temperature operation can reduce the electrical work requirement by supplying part of the reaction energy as heat. That does not make the total energy requirement disappear: a rigorous comparison must include steam generation, external heat, heat recovery, and other auxiliary loads. Thermal cycling, seals, material stability, and long-term degradation are important design challenges.

A different emerging family of proton-conducting ceramic electrolysis cells also exists. The SOEC half-reactions above describe the widely discussed oxygen-ion-conducting configuration; they should not be applied unchanged to proton-conducting ceramics.

6. Emerging anion exchange membrane (AEM) electrolysis

Anion exchange membrane electrolyzers combine an OH⁻-conducting solid polymer membrane with alkaline electrode chemistry. The charge carrier is hydroxide, as in conventional alkaline electrolysis, but the separator is a membrane rather than a conventional liquid-electrolyte diaphragm. Potential advantages include reduced reliance on precious-metal catalysts; durability, conductivity, water management, and commercial scale-up remain important engineering considerations.

AEM should not be confused with PEM: the mobile ion is OH⁻ in AEM and H⁺ in PEM. Nor should AEM be described as simply identical to traditional liquid-alkaline equipment. This article focuses on AWE, PEM, and SOEC as the three principal foundational families.

7. Thermodynamics: Gibbs energy, enthalpy, and voltage

For water electrolysis at specified temperature, pressure, and reactant/product states, the reaction Gibbs energy ΔG describes the minimum reversible non-expansion work, while reaction enthalpy ΔH describes the energy change. At approximately 25°C and standard conditions for liquid water, ΔG° ≈ 237.1 kJ/mol H₂ and ΔH° ≈ 285.8 kJ/mol H₂. Two moles of electrons are required per mole H₂.

Reversible voltage at specified state
E_{\mathrm{rev}}=\frac{\Delta G}{2F}

Here F ≈ 96,485 C/mol e⁻. The relation assumes consistent thermodynamic reaction and species states.

Thermoneutral voltage at specified state
E_{\mathrm{tn}}=\frac{\Delta H}{2F}

At 25°C for liquid-water electrolysis, this is approximately 1.48 V; it is not a universal constant across all temperatures or steam-feed states.

At 25°C and standard conditions for liquid-water splitting, these expressions give approximately 1.23 V reversible and 1.48 V thermoneutral. The difference is associated with the reversible heat term TΔS. For steam electrolysis, use steam-state thermodynamic properties at the actual operating temperature; do not carry the 25°C liquid-water values into a high-temperature SOEC calculation without correction.

State-dependent Nernst expression, simplified
E_{\mathrm{rev}}(T,p)=E^\circ_{\mathrm{rev}}(T)+\frac{RT}{2F}\ln\!\left(\frac{a_{\mathrm{H_2}}\,a_{\mathrm{O_2}}^{1/2}}{a_{\mathrm{H_2O}}}\right)

Activities are dimensionless and defined relative to appropriate standard states; for gases, fugacity-based activities are preferred at elevated pressure. Temperature dependence of the standard potential must also be included.

Worked example 1 — Reversible and thermoneutral voltage

Using ΔG° = 237.1 kJ/mol H₂, ΔH° = 285.8 kJ/mol H₂, and F = 96,485 C/mol e⁻, calculate the reversible and thermoneutral voltages for liquid-water electrolysis at 25°C.

  1. Convert kJ to J per mole of H₂.
  2. Divide each molar energy by 2F.
  3. Interpret the difference as an energy-balance term, not a direct estimate of a real cell’s losses.
E_{\mathrm{rev}}=\frac{237100}{2(96485)}\approx1.229\ \mathrm{V},\quad E_{\mathrm{tn}}=\frac{285800}{2(96485)}\approx1.481\ \mathrm{V}

Answer: Erev ≈ 1.23 V and Etn ≈ 1.48 V for the stated reference states.

8. Why a real cell needs more voltage: polarization

The measured operating voltage generally exceeds Erev because of activation overpotentials at the electrodes, ohmic resistance in the electrolyte/membrane, contacts, and components, and mass-transfer limitations. The decomposition below is an engineering model: the terms can depend on temperature, current density, hydration, bubbles, pressure, and local concentration.

Cell-voltage loss model
V_{\mathrm{cell}}=E_{\mathrm{rev}}+\eta_{\mathrm{act,a}}+\eta_{\mathrm{act,c}}+i\,R_{\mathrm{ASR}}+\eta_{\mathrm{mt}}

Here i is current density (A/m² or A/cm² consistently) and R_ASR is area-specific resistance in compatible units. The activation and transport overpotentials are positive loss magnitudes.

Activation losses reflect finite electrode reaction rates. Ohmic losses often increase approximately linearly with current density over a limited range. Mass-transport losses arise when reactants, products, bubbles, or local water availability constrain transport. High-temperature operation changes kinetics, electrolyte conductivity, and heat management, so different technologies have different polarization curves.

Schematic cell-voltage curve rising with current density, illustrating activation, ohmic and mass-transport losses.
Current density and geometric active area
i=\frac{I}{A_{\mathrm{active}}}

Current density is current per electrochemically active area. A geometric-area basis must be defined and used consistently.

Worked example 2 — Operating voltage from loss terms

A hypothetical cell at a fixed current density has E_rev = 1.23 V, total activation loss = 0.28 V, ohmic loss = 0.25 V, and mass-transport loss = 0.08 V. Estimate its operating voltage.

  1. Write the cell-voltage decomposition.
  2. Sum the three loss magnitudes: 0.28 + 0.25 + 0.08 = 0.61 V.
  3. Add the reversible voltage.
V_{\mathrm{cell}}=1.23+0.28+0.25+0.08=1.84\ \mathrm{V}

Answer: Approximately 1.84 V for this illustrative operating point.

Worked example 3 — Ohmic voltage drop

A cell operates at 1.5 A/cm² and has an area-specific resistance of 0.18 Ω·cm². Calculate its ohmic voltage loss.

  1. Multiply current density by area-specific resistance.
  2. Check that A/cm² × Ω·cm² produces volts.
  3. Do not add this term twice if it is already included in measured cell voltage.
\eta_{\mathrm{ohmic}}=(1.5\ \mathrm{A\,cm^{-2}})(0.18\ \Omega\,\mathrm{cm^2})=0.27\ \mathrm{V}

Answer: The ohmic contribution is 0.27 V.

9. Faraday’s law: linking current to hydrogen flow

For a cell producing hydrogen, two electrons correspond to one molecule of H₂. The theoretical hydrogen molar production rate is proportional to current. Faradaic efficiency ηF accounts for the fraction of current effectively converted to collected hydrogen. For N identical cells in electrical series, total stack hydrogen production is N times the per-cell production at the common stack current.

Hydrogen molar rate for N series cells
\dot n_{\mathrm{H_2}}=\frac{N\,\eta_F\,I}{2F}

Units: N dimensionless, η_F dimensionless, I in A = C/s, and F in C/mol e⁻; result is mol H₂/s.

Hydrogen mass flow rate
\dot m_{\mathrm{H_2}}=\frac{N\,\eta_F\,I\,M_{\mathrm{H_2}}}{2F}

Use M_H2 ≈ 0.002016 kg/mol. If cells operate in parallel or bypass modes, account for the actual electrical topology.

Worked example 4 — Hydrogen production from a single cell

A single electrolyzer cell operates at 1,000 A for 24 h with Faradaic efficiency 98%. Estimate the collected hydrogen mass.

  1. Charge passed = 1,000 × 86,400 = 86.4 million C.
  2. Moles H₂ = 0.98 × charge/(2F).
  3. Multiply by 0.002016 kg/mol.
m_{\mathrm{H_2}}=\frac{0.98(1000)(86400)(0.002016)}{2(96485)}\approx0.885\ \mathrm{kg}

Answer: Approximately 0.885 kg H₂/day for one cell.

Worked example 5 — Current density and stack production

A 100-cell series stack has an active area of 2,000 cm² per cell, current density 1.2 A/cm², and Faradaic efficiency 99%. Find current and hourly hydrogen production.

  1. Current = 1.2 × 2,000 = 2,400 A.
  2. Apply the N-cell Faraday relation over 3,600 seconds.
  3. Multiply moles by the hydrogen molar mass.
I=2400\ \mathrm{A},\quad \dot m_{\mathrm{H_2}}=\frac{100(0.99)(2400)(3600)(0.002016)}{2(96485)}\approx8.94\ \mathrm{kg\,h^{-1}}

Answer: 2,400 A stack current and approximately 8.94 kg H₂/h.

10. Stack power, specific energy, and efficiency

For N cells in series, stack DC power is approximately N I V_cell if the cells operate at a common average voltage. This is the electrical power entering the electrochemical stack; total facility AC demand includes power-conversion losses and auxiliaries. Always distinguish the measurement boundary before comparing efficiencies or specific electricity consumption (SEC).

Stack DC electrical power
P_{\mathrm{stack,DC}}=N\,I\,V_{\mathrm{cell}}

If individual cell voltages differ, use I times the sum of cell voltages instead of N times a single voltage.

Stack DC specific electricity consumption
\mathrm{SEC}_{\mathrm{stack}}=\frac{P_{\mathrm{stack,DC}}}{\dot m_{\mathrm{H_2}}}

When P is in kW and hydrogen rate in kg/h, SEC is in kWh/kg H₂. This relation must not be interpreted as plant AC SEC.

LHV-based electricity-to-hydrogen efficiency
\eta_{\mathrm{LHV,elec}}=\frac{33.33\ \mathrm{kWh\,kg^{-1}}}{\mathrm{SEC}_{\mathrm{electric}}}

Hydrogen LHV ≈ 33.33 kWh/kg; use a consistent stack or plant electrical input basis. For SOEC, report external heat input separately rather than implying electrical efficiency alone is total energy efficiency.

Worked example 6 — Stack electricity use

A 100-cell series stack operates at 800 A and 1.90 V per cell with 98% Faradaic efficiency. Estimate DC stack power, hourly H₂ production, SEC, and LHV-based electrical efficiency.

  1. Stack DC power = 100 × 800 × 1.90 / 1,000 = 152 kW.
  2. H₂ output = 100 × 0.98 × 800 × 3,600 × 0.002016 / (2 × 96,485) ≈ 2.95 kg/h.
  3. SEC = 152/2.95 ≈ 51.6 kWh/kg.
  4. LHV-based electrical efficiency = 33.33/51.6 ≈ 64.7%; auxiliary AC loads are excluded.
P_{\mathrm{DC}}=152\ \mathrm{kW},\quad \dot m_{\mathrm{H_2}}\approx2.95\ \mathrm{kg\,h^{-1}},\quad \mathrm{SEC}\approx51.6\ \mathrm{kWh\,kg^{-1}}

Answer: 152 kW, 2.95 kg/h, 51.6 kWh/kg, and 64.7% LHV-based stack electrical efficiency.

Efficiency figures in brochures may use LHV or HHV, DC stack input or AC plant input, beginning-of-life or degraded performance, and different pressure/temperature conditions. Two reported “efficiencies” are comparable only when these conventions match. At high temperature, an SOEC may have a favorable electrical SEC while requiring significant external thermal energy.

11. A closer look at heat and high-temperature electrolysis

The first-law energy balance for a steady electrolyzer includes electricity, inlet and outlet stream enthalpies, and heat transfer. In a simplified reversible conceptualization, reaction enthalpy equals reversible electrical work plus the reversible heat term. In a real system, overpotentials, sensible heating, steam generation, and heat losses determine whether heat must be supplied or rejected.

Thermodynamic relationship
\Delta H=\Delta G+T\Delta S

All terms must refer to the same reaction stoichiometry, temperature, pressure, and phase conventions.

At a fixed set of thermodynamic states, the thermoneutral voltage indicates a boundary between net heat absorption and net heat rejection in a simplified cell-level energy balance. The actual heat flow can differ because of inlet/outlet temperatures, phase changes, and system losses. Steam-electrolysis energy comparisons must report both electric and thermal inputs and the assumed heat-integration strategy.

Worked example 7 — Thermal-energy bookkeeping

A simplified high-temperature process receives 40 kWh of electrical energy and 12 kWh of externally supplied useful heat per kilogram H₂. Estimate the combined energy input, ignoring other auxiliaries.

  1. Keep electricity and heat as separate reported quantities.
  2. Add them only for a simple unweighted first-law input total.
  3. Recognize that energy quality differs; a full exergy or primary-energy analysis requires more information.
E_{\mathrm{input,combined}}=40+12=52\ \mathrm{kWh\,kg^{-1}}

Answer: 40 kWh/kg electrical plus 12 kWh/kg thermal, or 52 kWh/kg combined first-law input before auxiliaries.

12. Water treatment, gas separation, and balance of plant

Electrolyzer feedwater generally requires treatment appropriate to the technology, often including filtration, deionization, and control of ionic and organic contaminants. Pure-water requirements can be particularly stringent for PEM membranes and catalysts. Water chemically consumed by electrolysis is about 9 kg per kg H₂, but actual plant withdrawals can be higher because of purification reject, cooling, blowdown, and other needs.

Hydrogen and oxygen leave their respective electrode compartments, often accompanied by moisture. A practical system may include gas–liquid separators, demisters, dryers, oxygen handling, product-quality sensors, cooling equipment, compressors, and storage. The exact sequence and pressure conditions depend on process design. Gas cross-contamination and hazardous mixtures are safety-critical operating concerns.

Process diagram of electrical supply, rectifier, electrolyzer stack, water treatment, cooling, hydrogen conditioning and oxygen handling.
Stoichiometric water consumption
\frac{m_{\mathrm{H_2O,consumed}}}{m_{\mathrm{H_2}}}=\frac{18.015}{2.016}\approx8.94\ \mathrm{kg\,kg^{-1}}

Approximately 9 kg of water are chemically consumed per kg H₂. This is not a complete facility water-withdrawal factor.

Worked example 8 — Feedwater and oxygen coproduct

A plant makes 1,000 kg H₂/day. Estimate the theoretical reaction water consumption and oxygen coproduct using rounded ratios 9 and 8 kg per kg H₂.

  1. Water chemically consumed = 1,000 × 9.
  2. Oxygen coproduced = 1,000 × 8.
  3. Distinguish reaction water from facility water withdrawals and saleable oxygen.
m_{\mathrm{H_2O}}\approx9000\ \mathrm{kg\,d^{-1}},\quad m_{\mathrm{O_2}}\approx8000\ \mathrm{kg\,d^{-1}}

Answer: Approximately 9.0 tonnes/day water consumed and 8.0 tonnes/day oxygen formed.

Worked example 9 — Water treatment yield

If 9,000 kg/day of purified feedwater is required and a water-treatment system recovers 80% of incoming raw water, estimate raw-water intake, neglecting all other losses.

  1. Write recovered water = recovery fraction × raw intake.
  2. Divide 9,000 by 0.80.
  3. Additional cooling and cleaning water, if present, would be separate.
m_{\mathrm{raw}}=\frac{9000}{0.80}=11250\ \mathrm{kg\,d^{-1}}

Answer: 11.25 tonnes/day raw-water intake under the stated simplified assumptions.

13. Variable renewables, part load, and start–stop operation

A solar- or wind-connected electrolyzer experiences variations in input power. The plant controller must coordinate the DC rectifier, current ramps, temperatures, pressure differentials, gas purity, water flow, and shutdown sequences. PEM stacks often have attractive dynamic-response characteristics, but the achievable ramp rate and turndown of a complete system depend on its auxiliaries and safety limits. Modern alkaline systems may also be designed for flexible operation.

For high-temperature SOEC, large thermal gradients and repeated thermal cycles can create additional stress and durability concerns. Operating near the stack’s design temperature, integrating heat, and limiting damaging thermal cycling can matter more than instantaneous electrochemical response. A technology comparison must include the renewable power profile and the thermal plant, not only a catalogued stack efficiency.

Simplified annual hydrogen production
m_{\mathrm{H_2,year}}=\frac{P_{\mathrm{rated,AC}}\,(8760\ \mathrm{h})\,f_{\mathrm{use}}}{\mathrm{SEC}_{\mathrm{plant,AC}}}

f_use is equivalent full-load utilization on the same AC power boundary; SEC must reflect the operating mix. The expression is a preliminary annual estimate, not a dynamic dispatch simulation.

Worked example 10 — Renewable-driven annual hydrogen output

A 15 MW electrolyzer plant operates at 60% equivalent full-load utilization, with average AC specific electricity use of 52 kWh/kg. Estimate annual hydrogen output and stoichiometric water consumption.

  1. Annual electrical input = 15,000 kW × 8,760 h × 0.60 = 78.84 GWh.
  2. Divide 78,840,000 kWh by 52 kWh/kg.
  3. Multiply the hydrogen mass by approximately 9 kg water/kg H₂.
m_{\mathrm{H_2}}=\frac{15000(8760)(0.60)}{52}\approx1.516\times10^6\ \mathrm{kg\,yr^{-1}}

Answer: Approximately 1,516 tonnes H₂/year and 13,645 tonnes/year of reaction water.

14. Durability, failure mechanisms, and safety

Electrolyzer lifetime is affected by voltage rise, catalyst and membrane changes, electrode or interconnect corrosion, electrolyte contamination, thermal cycling, gas crossover, seal degradation, and operating practices. A rising cell voltage at fixed current and conditions raises specific electricity consumption. Durability metrics should distinguish stack operating hours, calendar life, replacement intervals, and degradation under actual duty cycles.

Hydrogen has a wide flammability range in air and requires engineering controls: leak detection, ventilation, suitable electrical equipment, pressure protection, purge procedures, gas separation, and adherence to relevant codes and standards. Oxygen-rich environments create separate fire hazards. Alkaline electrolyte can be corrosive; SOEC equipment introduces high-temperature hazards. Hydrogen production is an industrial chemical process, not a classroom DIY activity.

Worked example 11 — Impact of cell-voltage degradation

A cell voltage increases from 1.85 V to 1.95 V at the same current and Faradaic efficiency. Estimate the increase in stack electrical SEC if η_F = 0.98 and other conditions are unchanged.

  1. The increase is ΔV = 0.10 V.
  2. For the same Faradaic efficiency, SEC rises proportionally with cell voltage.
  3. Use ΔSEC = ΔV × 2F/(M_H₂ × 3.6 × 10⁶ × η_F).
\Delta\mathrm{SEC}=\frac{0.10(2)(96485)}{(0.002016)(3.6\times10^6)(0.98)}\approx2.71\ \mathrm{kWh\,kg^{-1}}

Answer: Approximately 2.71 kWh/kg H₂ additional stack electricity, excluding other changing losses.

15. Choosing between alkaline, PEM, and SOEC

Conventional alkaline: mature commercial supply chains, often non-precious catalysts, liquid alkaline electrolyte, and a long operating history. Evaluate separator performance, electrolyte handling, footprint, allowable turndown, pressure design, and gas purity. PEM: compact and dynamically responsive with solid proton-conducting membranes; evaluate deionized-water needs, catalyst/material supply, membrane life, and differential pressure. SOEC: attractive where high-temperature heat/steam can be integrated; evaluate total thermal and electrical energy, start-up and thermal cycling, sealing, and long-term durability.

There is no universal ranking by “efficiency” or cost. A useful comparison uses the same system boundary and project conditions: AC electricity consumption, heat input, hydrogen delivery pressure and purity, capacity factor, capital cost, replacement schedule, water quality, plant availability, and product demand. Technology-specific operating-temperature ranges are illustrative, not equipment specifications.

The U.S. Department of Energy electrolysis overview explains the main ion-transport mechanisms, while the IEA electrolyser technology review discusses technology readiness and deployment. DOE technical-target tables distinguish targets from current achieved performance; neither should be treated as a guaranteed vendor specification.

16. Practice questions and fully worked answers

Where are hydrogen and oxygen generated in a water electrolyzer?

Reveal worked answer

Hydrogen forms at the cathode (reduction) and oxygen at the anode (oxidation), regardless of whether the device is alkaline, PEM, or oxygen-ion-conducting SOEC.

Which ion crosses a conventional alkaline electrolyte?

Reveal worked answer

OH⁻ moves from cathode toward anode.

Which ion crosses a PEM electrolyte?

Reveal worked answer

H⁺ (protons) move from anode toward cathode.

Which ion crosses a typical oxygen-ion-conducting SOEC ceramic?

Reveal worked answer

O²⁻ moves from the steam/hydrogen electrode toward the oxygen electrode.

Balance the PEM cathode half-reaction for formation of two H₂ molecules.

Reveal worked answer

4H⁺ + 4e⁻ → 2H₂.

A cell carries 200 A. How much electric charge passes in 30 minutes?

Reveal worked answer

Q = I t = 200 × 1,800 = 360,000 C.

At 2 A/cm² and 1,500 cm² active area, calculate current.

Reveal worked answer

I = i A = 3,000 A.

A 40-cell stack carries 200 A at 1.95 V/cell. Estimate DC stack power.

Reveal worked answer

P = N I V = 40 × 200 × 1.95 = 15,600 W = 15.6 kW.

At 1.5 A/cm² and area-specific resistance 0.18 Ω·cm², what is the ohmic loss?

Reveal worked answer

0.27 V.

Why does a measured cell voltage exceed reversible voltage under load?

Reveal worked answer

Electrode activation, ionic/electronic ohmic resistance, and mass-transfer limitations introduce additional voltage losses.

Why is a PEM electrolyzer not the same as a PEM fuel cell?

Reveal worked answer

They may share membrane technology, but an electrolyzer consumes electrical energy to split water, whereas a fuel cell consumes fuel and oxidant to generate electricity.

Explain why SOEC electrical SEC alone cannot establish overall efficiency.

Reveal worked answer

SOEC also requires thermal energy and steam preparation; heat and electricity inputs must be reported on consistent system boundaries.

For 500 kg H₂/day, estimate theoretical water consumption.

Reveal worked answer

Approximately 500 × 9 = 4,500 kg/day (4.5 tonnes/day) of chemically consumed water.

A 2.5 MW plant has average AC SEC 53 kWh/kg. Estimate H₂ production at rated load.

Reveal worked answer

2,500 kW ÷ 53 kWh/kg ≈ 47.2 kg H₂/h.

What is the difference between Faradaic efficiency and LHV-based electrical efficiency?

Reveal worked answer

Faradaic efficiency measures the fraction of charge yielding collected hydrogen; LHV-based electrical efficiency compares hydrogen chemical energy output to electrical energy input.

A cell degrades by +0.10 V at fixed current and η_F. What happens to SEC?

Reveal worked answer

SEC rises; at η_F = 0.98, the idealized increase is about 2.71 kWh/kg at the stack boundary.

List three key plant auxiliaries omitted from simple stack-only power calculations.

Reveal worked answer

Examples include AC/DC rectification, water treatment, pumps, cooling, gas drying, compressors, and control/safety equipment.

What is the primary process hazard of H₂/O₂ crossover?

Reveal worked answer

A combustible gas mixture can form; product-gas separation, monitoring, and safe shutdown controls are critical.

17. Frequently asked questions

Does water electrolysis produce hydrogen directly from renewable electricity? Electrolysis can be powered by renewable electricity, but the plant’s actual electricity supply and lifecycle boundary determine whether the hydrogen qualifies as low emissions. The electrochemical process itself does not guarantee a particular carbon intensity.

Which electrolyzer technology is best for solar or wind? No technology is always best. PEM is often considered for fast dynamics; alkaline systems can also be engineered for flexible operation. SOEC performance depends strongly on high-temperature heat integration and thermal cycling. Project-specific modeling is essential.

What is the difference between an electrolyzer cell and stack? A cell is one electrochemical unit. A stack combines many cells, commonly in electrical series, to achieve a useful production rate and voltage.

What voltage is needed for electrolysis? About 1.23 V is the reversible voltage for liquid-water splitting at 25°C standard conditions, but practical cell voltage is higher under load and depends on technology, temperature, pressure, and current density.

Why is the 1.48 V thermoneutral voltage not the same as a universal minimum voltage? It relates to reaction enthalpy for a particular thermodynamic state and phase convention. Reversible electrical work is related to Gibbs energy; real operation also includes heat exchange and losses.

18. Key takeaways and next lesson

Electrolyzer chemistry is governed by the same overall water-splitting reaction, but ion transport distinguishes alkaline (OH⁻), PEM (H⁺), and oxygen-ion SOEC (O²⁻) technologies. Cell voltage, current density, Faradaic efficiency, and operating conditions determine stack production and electricity demand. For meaningful comparisons, account for the entire plant and—in SOEC designs—the required thermal input.

Next: Green Hydrogen Production Calculations: Electrolyzer Efficiency, Energy Consumption, and Worked Examples, which will extend these concepts to plant-level energy and mass balances, equipment sizing, renewable supply matching, degradation, and economics. Earlier foundational renewable electricity lessons include solar energy and wind turbine power calculations.