Industrial furnaces, kilns, dryers, engines and hot process streams discharge thermal energy that may be too cool or too dispersed for conventional steam power generation. An organic Rankine cycle (ORC) converts part of that heat into shaft work and electricity with a closed-loop working fluid selected for the actual temperature range. An ORC does not produce electricity without a temperature difference: it accepts heat from a source and rejects the remainder to a cooler sink. Whether power generation is sensible depends on temperature, available duty, operating hours, competing process-heating demands, cooling requirements, equipment losses and project costs. The UK Energy Technology List, U.S. DOE-CHP eCatalog and government waste-heat guidance describe this technology for industrial and other waste-heat-to-power applications [1–3].
Learning objectives
- Trace the working fluid through an evaporator, expander, condenser and pump using consistent thermodynamic state labels.
- Distinguish recoverable heat duty from useful net electricity , and calculate both first-law and Carnot efficiency without mixing boundaries.
- Evaluate a complete ORC teaching case with the first-law balances, cooling-water sizing, heat-source screening and electrical parasitic loads.
- Explain why fluid selection, minimum temperature approaches and off-design operation are central to engineering feasibility.
- Perform a transparent annual-output and simple-payback screening without treating illustrative costs as quotations.
- Identify when direct heat reuse, an industrial heat pump or an ORC is a better starting point for waste-heat recovery.
1. The engineering problem: turning rejected heat into power
A process may reject hot exhaust at 200°C while drawing electricity from a grid. A heat exchanger can capture some exhaust heat, but power generation requires a heat engine and a colder heat sink. Conventional water–steam Rankine cycles are often favored for larger, hotter duties. ORCs use refrigerants, hydrocarbons, siloxanes or other appropriate organic compounds and may operate where a small steam turbine would be impractical. The suitable temperature range is not one universal threshold: published applications and specifications span considerably different source temperatures, capacities and cooling conditions [1–4].
For a nearly constant-heat-capacity hot stream, a preliminary heat inventory is
Temperatures in this difference can be expressed in °C because only a temperature difference is used; mass flow is in kg/s, heat capacity in kJ/(kg K), and duty in kW. It is only a heat inventory. The actual ORC heater duty is constrained by finite heat-transfer temperature approaches, hot-stream cooling limits, fouling, pressure drops and phase-change behavior. Nor does one kilowatt of recoverable heat imply one kilowatt of electric power.
2. Four components and the closed working-fluid circuit
The pump raises the pressure of condensed liquid from state 1 to state 2. The heater/evaporator transfers heat from the industrial source and sends high-pressure vapor to state 3. The expander drives a shaft and generator as the fluid passes from 3 to 4. The condenser rejects heat to cooling water or air and returns the fluid to the liquid state 1. Some practical ORCs also have internal recuperators, preheaters, superheaters and intermediate thermal-oil loops. A separator or special expander design may be necessary depending on fluid and operating conditions.

Figure 1. Basic organic Rankine cycle. State 1: condenser outlet; 2: pump outlet; 3: expander inlet; 4: expander outlet. Heat source and heat sink remain separate from the sealed working-fluid circuit.
A common naming mistake is to label the evaporator as a boiler and assume the working fluid is water. An ORC is a Rankine-like heat-engine cycle, but its fluid properties, vapor behavior, component hardware and safety requirements differ substantially from a conventional steam cycle. A heat pump is the reverse objective: it consumes work to upgrade heat; the ORC consumes heat to deliver work. The equipment cannot be switched between these modes merely by reversing a valve.
3. First-law energy balances: state enthalpy to net power
For a steady-flow control volume with negligible kinetic and potential energy changes, the heater, expander, condenser and pump have idealized enthalpy-rate balances. With working-fluid mass flow (ṁ_f) and specific enthalpies (h_i) in kJ/kg:
For the idealized thermal cycle, the net shaft output is
and the thermal efficiency at that boundary is
This identity assumes a closed steady cycle, negligible heat loss outside the specified heater/condenser, and a pump and expander treated consistently as shaft devices. It is not a grid-connection electricity efficiency. For the plant power-export boundary, include generator and pump-motor performance and all auxiliaries:
Here (η_g) is generator electrical conversion efficiency and (η_m,p) is pump motor efficiency. Auxiliary loads include cooling fans, cooling-water pumps, controls and potentially the external hot-side circulation loop. Never subtract pump electricity twice: the ORC working-fluid pump and external process/cooling pumps belong to separate explicitly stated terms. A meaningful engineering comparison uses net electrical power:
4. Expansion and pumping efficiencies
A detailed cycle model begins with source and sink temperatures, pressures, pinch requirements and thermodynamic properties. For a turbine/expander, an isentropic reference outlet has (s_4s=s_3) at the actual outlet pressure. The expander efficiency is
where an irreversible real expansion generally makes (h_4) larger than (h_4s) for a given inlet and outlet pressure. For the pump, with isentropic liquid outlet (h_2s),
For a nearly incompressible liquid, the isentropic enthalpy rise is often approximated by
using consistent units for pressure and specific volume. These formulas are not substitutes for a validated fluid property model, pressure drops, allowable turbine wetness, fluid degradation limits or actual equipment performance maps [4–6].
5. Temperature limits and the Carnot benchmark
The reversible efficiency for a heat engine operating between two isothermal reservoirs is
This is an ideal upper bound, not a prediction of a vendor ORC's achievable efficiency. For a representative evaporating-temperature level of 130°C and condensing-temperature level of 35°C, use (T_h=403.15 K) and (T_c=308.15 K):
Real exchanger duties occur across varying source and sink temperatures and nonzero approaches. A rigorous reversible limit for finite thermal streams generally requires an exergy analysis rather than plugging average inlet temperatures into the two-reservoir Carnot formula. The heat-engine availability of a small heat increment transferred at source temperature (T) relative to environment (T_0) is
Temperature appears in kelvin in the exergy expression. Losses from finite temperature differences, expander irreversibility, fluid pressure drops, pump losses and generator conversion consume a portion of that ideal potential.

Figure 2. Qualitative temperature–entropy sketch. The depicted saturation envelope and path locations are conceptual only: their real curvature and dry/wet expansion behavior depend on the selected working fluid and cycle pressure.
6. Fully worked example: industrial exhaust coupled to an ORC
A teaching case uses an exhaust source entering the ORC heater at 200°C. The proposed working fluid absorbs heat from this source and nominally evaporates at approximately 130°C, while the condenser operates near 35°C. Assume an internally consistent set of illustrative enthalpy differences for a basic cycle. These numbers are not property outputs for a specified refrigerant or hydrocarbon and therefore do not prove a feasible commercial operating point. They demonstrate how to perform a defensible energy accounting exercise before using real properties in an engineering design.
Given design-screening assumptions: Working-fluid flow (ṁ_f=8.0 kg/s). State enthalpies (h_1=240), (h_2=245), (h_3=510), (h_4=470 kJ/kg). Generator efficiency (η_g=0.96). For transparent bookkeeping, the pump motor efficiency is assumed 1.00, an intentionally optimistic simplification. External hot-side, cold-side and control auxiliaries use 11.2 kW altogether. We compare this model against realistic efficiencies later rather than presenting it as a plant recommendation.
Step A. Heat delivered by the industrial source.
Step B. Gross expander shaft power.
Step C. Working-fluid pump input.
Step D. Condenser heat rejection.
Step E. Check the cycle heat balance, using shaft work.
The equality is important. The 2,120 kW heat input is distributed between 1,840 kW of condenser rejection and 280 kW of net shaft work. Generator losses and auxiliary loads occur outside that four-component thermodynamic bookkeeping boundary.
Step F. Net electricity with explicit auxiliaries.
Step G. Thermal and net electrical efficiencies.
Thus, 2.12 MW of heat transferred to the ORC becomes 0.256 MW of net electricity, at the explicitly stated electrical boundary. The other 1.864 MW comprises condenser heat rejection and electrical conversion/auxiliary losses in different locations. It would be incorrect to say 1.864 MW all enters the condenser: the condenser itself rejects 1.840 MW.
Step H. Check hot-stream heat inventory and minimum approach. Suppose the hot exhaust has cₚ,ₕ = 1.05 kJ/(kg·K), flows at a constant rate, enters at 200°C and leaves at 150°C. Its required mass flow is
The exhaust outlet of 150°C exceeds the nominal 130°C boiling level by 20 K, so there is no obvious negative hot-end approach against that nominal evaporating level. This is only a preliminary plausibility screen. Full temperature–heat composite curves are needed because the working fluid is also sensible-heated and the source has finite heat capacity.
Step I. Size cooling water. If condenser heat is removed by water warming from 20°C to 30°C, take cₚ,w = 4.18 kJ/(kg·K):
A nominal 35°C condensing temperature gives a 5 K warm-end approach to the 30°C cooling-water outlet. Again, detailed equipment selection must confirm the exchanger's temperature profile, pressure drops and cooling system availability.

Figure 3. Worked case with distinct thermodynamic and electrical boundaries. All values are teaching assumptions, not a specific commercial ORC data sheet.
How the example changes for a real pump motor
If a real pump motor has electrical efficiency (η_m,p=0.90), its electricity demand is (40/0.90=44.44) kW, not 40 kW. With the same external auxiliaries, net electricity falls to (307.2-44.44-11.2=251.56) kW. The extra 4.44 kW is a motor loss outside the modeled working-fluid cycle, unless a more detailed pump boundary includes its heat recovery. This is why equipment electrical boundaries must be documented before discussing ORC performance.
7. Working-fluid selection: not just the boiling point
A fluid's atmospheric boiling point by itself does not determine a good ORC design. The relevant properties are saturation pressure and temperature at the operating states, critical temperature, vapor-density and volumetric-flow effects, viscosity, heat-transfer coefficient, latent heat, thermal stability and the slope of the saturation vapor curve. A 'dry' fluid may remain superheated during expansion, opening the possibility of internal heat recuperation; a 'wet' fluid may require inlet superheat to avoid damaging liquid droplets. A 'near-isentropic' fluid behaves differently again. Working-fluid optimization is a combined thermodynamic, mechanical, environmental and economic problem [4–6].
Examples of investigated fluid families include hydrocarbons, certain refrigerants and hydrofluoroolefins, and siloxanes. No fluid is universally safest or most efficient. Candidate selection must evaluate flammability classification, toxicity, leakage, global-warming potential, ozone impact, chemical compatibility, decomposition products, local refrigerant regulations and maintenance practices. Fluid phase behavior must be checked with a suitable database such as CoolProp, REFPROP or appropriately verified correlations. A generic article cannot certify a refrigerant or guarantee compliance for a jurisdiction.
8. Heat-exchanger and pinch integration
Before adding an ORC, create a site heat inventory, identify process requirements and apply the pinch principles already introduced in our industrial heat-recovery series. A stream of valuable 200°C heat should not automatically be converted to 12% electricity if the same heat could displace substantial fuel input in an important process. Recover higher-value direct process heat first where appropriate; then evaluate an ORC from the remaining profile. This is a design prioritization heuristic, not an economic law: site electricity tariffs, heat demand, capital costs and carbon factors may change the ranking [2,3,7].
For a heater or condenser with an approximate overall heat-transfer coefficient, the familiar relationship is
where (F) corrects for the exchanger configuration where required. When streams change phase or have strongly varying heat capacity, divide the duty into zones, perform a temperature–enthalpy match and enforce a positive minimum temperature difference everywhere. A single average (U) and logarithmic mean temperature difference (LMTD) can be misleading if applied across preheating, evaporation and superheating without segmentation. Actual hot-side heat transfer may use an intermediate thermal-oil loop, which adds complexity, pressure loss and temperature approach.

Figure 4. Upper-bound Carnot efficiency increases with source temperature for a fixed 35°C sink. The illustrative 8–15% band is a visual teaching reference, not a calculated equipment prediction; actual net efficiency depends on fluid, pinch points, pressures and parasitic loads.
9. Real operating concerns and off-design performance
Unlike the constant numbers used in a classroom example, industrial heat sources vary hourly, seasonally and by operating schedule. A plant evaluation should retrieve at least representative time-series data for source temperature, mass flow and downstream constraints. The heater may require bypass and isolation provisions; the expander must stay within approved operating envelopes; controls must coordinate cooling availability, process safety, overpressure protection and grid connection. Off-design operation is not merely 'nominal efficiency times annual hours' [7,8].
Key risks and remedies: A fouling heat exchanger reduces useful temperature difference; include accessible cleaning provisions. Loss of cooling can raise condensing pressure and cut power; consider the worst ambient condition. Incompatible fluids, leakage and decomposition create safety concerns; use suitable mechanical and regulatory design. Intermittent source heat reduces utilization; model load distributions before sizing the turbine. Overstated net output can result from ignoring fan, cooling-water, circulating-oil and external-pump electricity; account for them at one consistent boundary. Be cautious about vendor claims that use gross turbine output while the feasibility model values net grid-export power.
10. Annual electricity, costs and payback: screened example
To evaluate the teaching case, suppose measured operating hours eventually support 7,000 full-power-equivalent hours/year at 256 kW net. Assume on-site electricity has an avoided cost of US$0.12/kWh, total incremental ORC capital cost is US$1,400,000, and annual additional operations and maintenance expense is US$35,000. These are invented example assumptions, not present-day vendor quotes or electricity tariffs in any country.
Simple payback is a crude screening indicator, not a discounted-cash-flow investment recommendation. Real projects should use net present value, internal rate of return, a documented power dispatch and tariff structure, equipment life, downtime, degradation, cost of capital, incentives and tax treatment. The project must also consider production downtime during installation, displaced heat uses and backup cooling needs. If the heat stream operates only 3,500 full-power-equivalent hours, annual net electricity halves, which can dramatically change the economics.
A simple operational electricity-avoidance screen may be expressed as
where (f_grid) is an assumed avoided marginal or accounting emission factor in kg CO₂/kWh and the result is metric tonnes CO₂/year. For a hypothetical factor of 0.40 kg CO₂/kWh, the arithmetic gives 716.8 t CO₂/year. This is not an audited project reduction: grid-factor choice, heat-process changes, construction, fluid leaks, competing recoveries and attribution can materially change the result. Using waste heat does not make the entire system automatically 'zero carbon'.
11. Comparison: ORC, industrial heat pump, or direct heat recovery?
Direct heat recovery generally deserves first consideration if a hot process stream can directly meet another useful process duty without upgrading. Industrial heat pumps consume electricity to lift low-temperature heat to a more useful temperature; heating COP is the relevant output-to-input ratio. ORCs extract work from an available hot source and require a colder sink; net electricity divided by thermal input is the relevant efficiency. These are not interchangeable metrics. Some integrated sites deploy more than one technology, but combined heat-cascade and utility optimization should prevent double-counting the same heat source.
For further study, read RENEWIOSITY's Industrial Waste Heat Recovery: Sources, Technologies and Opportunities and Industrial Heat Pumps and Low-Temperature Heat Recovery. A prior heat exchanger network lesson in the same topic hub explains why temperature matching matters before equipment selection.
12. Five practice problems with solutions
Problem 1: Available source duty. A thermal-oil return stream flows at 5 kg/s with (c_p=2.4 kJ/(kg·K)). It may cool from 180°C to 130°C. Find its heat inventory. Solution: (5×2.4×50=600) kW. This is recoverable thermal inventory, not net electric output, and cannot be transferred unless exchanger approaches permit.
Problem 2: ORC electric efficiency. An ORC receives 900 kW of heat and produces 108 kW of gross electricity. Total circulation and cooling auxiliaries consume 21 kW. Find net electrical power and net conversion efficiency. Solution: (108-21=87) kW; (87/900=9.67%).
Problem 3: Carnot ceiling. An ideal heat engine runs between isothermal 150°C and 30°C reservoirs. Find the reversible efficiency. Solution: (1-(303.15/423.15)=28.36%). Treat this only as a theoretical two-reservoir benchmark.
Problem 4: Condenser water. An ORC rejects 1.50 MW to cooling water warming by 8 K. Assuming (c_p=4.18 kJ/(kg·K)), estimate the water mass flow. Solution: (1500/(4.18×8)=44.86) kg/s. Pressure drops, cooling-tower conditions and worst-case ambient remain to be assessed.
Problem 5: Simple payback. A 120 kW net ORC provides 6,000 full-power-equivalent hours/year. Avoided electricity is worth US\(0.10/kWh; O&M costs US\)12,000/year; installed project cost is US\(480,000. **Solution:** annual generation = 720,000 kWh; gross savings = US\)72,000/year; net savings = US$60,000/year; payback = 8.0 years before financing, taxes or degradation.
13. Engineering checklist before procurement
- Measure a representative heat-source duration curve, including temperature and flow.
- Confirm process heat reuse options and the opportunity cost of cooling the available stream.
- Obtain a reliable heat-sink and seasonal ambient-temperature profile.
- Enforce minimum exchanger temperature approaches over the entire temperature–heat curve.
- Compare candidate working fluids with credible property models, safety codes and relevant refrigerant regulations.
- Get vendor curves for expander output and efficiency at design and off-design conditions.
- Count generator losses, internal pump motor losses and all external parasitic loads in net electricity.
- Model installation costs, dispatch hours, maintenance, availability, displaced utilities, payback and NPV.
- Review containment, emergency shutdown, fire protection, pressure relief and fluid disposal.
- Use independently checked plant data and pilot measurements before promising savings or emissions reductions.
14. Key takeaways
An ORC is a useful tool for converting certain low- and medium-temperature industrial heat streams into electricity, particularly when no higher-value direct heat use is available. Its heat input, net shaft work, net electric output and condenser load are different quantities and must not be conflated. The worked example converts 2,120 kW of transferred heat into 256 kW of illustrative net electrical power, an explicitly calculated 12.08% net electric efficiency. That result does not prove a particular fluid or commercial unit can achieve the assumed states. Correct engineering decisions begin with real plant heat profiles, a feasible fluid and heat-exchanger design, explicit electrical auxiliaries, and a site-specific techno-economic study.
Technical discussions describe general principles; site-specific engineering decisions require appropriate professional evaluation.