Geothermal Engineering Toolbox

Eleven engineering modules covering geothermal resources, wellbores, flash and binary cycles, ground-source heat exchangers, EGS, two-phase flow, Kalina screening, and project economics. Explore assumptions, charts and preliminary screening results.

0 · Theory, definitions and governing equations

Every number produced by the other tabs is derived from the relations on this page. Symbols follow standard geothermal practice (Grant & Bixley, Geothermal Reservoir Engineering; ASHRAE Handbook—HVAC Applications ch. 34; IAPWS‑IF97 for water properties).

Key terms and definitions

Geothermal gradientRate of temperature increase with depth, dT/dz — typically 20–40 °C/km in stable continental crust, 60–150 °C/km in a geothermal field.
Heat flow (q″)Conductive heat flux through the crust, q″ = k·dT/dz. World average ≈ 65 mW/m²; prospects exceed 100–150 mW/m².
Thermal conductivity (k)Heat conducted per metre per kelvin, W/(m·K): granite 2.5–3.5, sandstone 2–4, saturated clay 1.5–2.2, grout 1.5–2.5.
Thermal diffusivity (α)α = k/(ρcp), m²/s — how fast a temperature disturbance spreads in the ground; sets long-term borehole behaviour.
Volumetric heat capacity (ρcp)Heat stored per m³ per K: rock ≈ 2.0–2.6 MJ/(m³·K), water 4.18 MJ/(m³·K). Dominant term in heat-in-place estimates.
Geothermal reservoirA permeable, fluid-filled rock volume bounded by a caprock that can deliver heat economically — described by temperature, pressure, permeability, porosity and chemistry.
Porosity (φ) / permeability (κ)φ is void fraction (storage); permeability (m², darcy) is the ability to transmit fluid. A good reservoir needs both plus recharge.
Recovery factor (Rf)Fraction of heat in place realistically extracted over a project life; 0.05–0.25 for hydrothermal systems.
Discharge enthalpySpecific enthalpy of fluid entering the well, kJ/kg. Liquid-dominated wells have h ≈ hf(Tres); a two-phase feed has a steam fraction that raises h.
Flashing / separatorWhen pressure falls below the saturation pressure the brine boils. A separator splits the mixture into steam (to the turbine) and brine (to reinjection or a second flash).
Steam quality (x)Vapour mass fraction, x = (h − hf)/hfg. Turbine exhaust quality should stay above ≈ 0.88 to limit blade erosion.
NCG (non-condensable gases)Mostly CO₂ and H₂S, 0.1–5 % by weight of steam. They raise condenser pressure, need gas extraction and drive corrosion and emissions.
Single / double flashCycles in which steam separated at one or two decreasing pressures is expanded through a turbine and condensed.
Binary / ORC plantA secondary fluid (isobutane, n‑pentane, R‑134a, ammonia) boils against the brine in a heat exchanger and drives a turbine — enabling power from 90–180 °C brine with full reinjection.
Kalina cycleBinary cycle on an ammonia–water mixture whose boiling temperature glides, which can improve heat-source temperature matching in some configurations; relative performance must be established from a validated cycle comparison.
Utilisation efficiency (ηu)Net output divided by the exergy of the produced fluid relative to the sink — a fairer yardstick than first-law efficiency, since it measures how much of the available work is captured.
Specific steam consumption (SSC)kg of steam per kWh of net output; 5–10 kg/kWh for flash plants, and a direct indicator of turbine and condenser health.
ExergyMaximum useful work from a stream as it equilibrates with the dead state: ė = (h − h₀) − T₀(s − s₀).
ReinjectionReturning spent brine and condensate to the reservoir to hold pressure, sustain output and avoid surface disposal; typically 60–100 % of produced mass.
Silica scaling / corrosionAmorphous silica polymerises as brine cools below ~150 °C (limits reinjection temperature); CO₂ + H₂S with chlorides cause acidic corrosion and drive materials selection.
Productivity index (PI)Deliverability, PI = ṁ/(pres − pwf), kg/s per bar; set by permeability-thickness and skin.
Borehole heat exchanger (BHE)Closed U-tube in a grouted borehole exchanging heat with the ground by conduction — the coupling used by ground-source heat pumps.
Borehole thermal resistance (Rb)Resistance between circulating fluid and borehole wall, m·K/W; 0.06–0.15 typical, lowered by thermally enhanced grout and wider shank spacing.
Ground thermal resistance (Rg)Transient resistance of the surrounding ground from the line-source or g‑function solution; grows logarithmically with time.
Entering fluid temperature (EFT)Fluid temperature entering the heat pump. Design limits (e.g. −2 … 35 °C) set the borehole length; a drifting EFT signals an undersized or load-unbalanced field.
Heating / cooling COPHeat-pump coefficient of performance (heat delivered per unit electricity) and cooling energy efficiency ratio. Ground load differs from building load by the compressor power.
Capacity factor (CF)Annual generation ÷ (rated power × 8760 h). High values are possible, but actual output depends on maintenance, reservoir decline, and plant availability.
LCOELevelised cost of electricity — the constant price per MWh that exactly recovers discounted costs over the project life; highly project-specific; cost ranges must specify date, resource, location, and financing basis.
Capital recovery factor (CRF)CRF = i(1+i)ⁿ/[(1+i)ⁿ − 1], converting capital cost into an equivalent annual payment at discount rate i over n years.
Utilisation vs efficiencyA plant can be efficient and still waste most of the resource exergy; always report ηu alongside ηth when comparing technologies.
1 · Resource & conductive heat transfer
Fourier's law — conductive heat flux
Linear geotherm, gradient G
Thermal resistance of a layer
Heat diffusion equation
Heat in place (volumetric method)
Recoverable heat
Equivalent electrical potential
2 · Wellbore thermodynamics & flashing
Hydrostatic bottom-hole pressure
Clausius–Clapeyron: shape of the saturation curve
Flashing depth of a hydrostatic column
Adiabatic flash — steam quality
Liquid enthalpy approximation
Productivity index
Exergy of the produced fluid
3 · Flash power cycles
Steam fraction at the separator
Steam and brine flows
Isentropic turbine exhaust state
Gross turbine power
Net power after parasitics
Specific steam consumption
Condenser duty and cooling water
First-law efficiency
Utilisation (exergetic) efficiency
4 · Binary / ORC cycles
Carnot limit between source and sink
Practical cycle efficiency (ORC)
Heat taken from the brine
Brine outlet fixed by pinch
Log-mean temperature difference
Heat-exchanger sizing
Net binary output
5 · Borehole heat exchangers
Line-source solution, γ = 0.5772
Effective ground resistance
ASHRAE heating borehole length
ASHRAE cooling borehole length
Ground-side peak loads
Borehole resistance (grout + film)
Number of boreholes
6 · Direct-use hydraulics and heat loss
Flow rate and velocity
Reynolds number
Colebrook–White friction factor
Darcy–Weisbach with minor losses
Pumping power
Insulation + buried-soil resistance per metre
Heat loss and temperature drop
7 · Project economics
Capital recovery factor
Levelised cost of electricity
Annual generation
Net present value
Internal rate of return
Risked cost of a production well
LCOE in cost-per-kW form
8 · EGS hydraulics and stimulation
Vertical (overburden) stress at depth z
Horizontal stress from uniaxial-strain (K₀ is measured, not assumed, in the field)
Pore pressure, normally hydrostatic (≈9.8 MPa/km)
Breakdown pressure — Hubbert–Willis, vertical well
Injectivity index, steady radial Darcy flow
Effective wellbore radius of an infinite-conductivity fracture (Prats)
Thermoelastic reduction of horizontal stress on cooling
Shear reactivation criterion — the Mohr circle touches the friction envelope
Cooling needed to self-stimulate the fracture network
Dimensionless fracture conductivity; below ~10 the fracture itself chokes the flow
Thermal breakthrough — the swept rock volume must lose its heat
Bulk heat capacity of the reservoir rock

Definitions. EGS (enhanced/engineered geothermal system): a reservoir whose permeability is created by stimulation rather than found. Breakdown pressure: bottom-hole pressure at which a tensile fracture opens against σh. Shear dilation: opening of natural fractures by sliding on rough surfaces, the main permeability-creation mechanism when cooling relieves normal stress. SRV: stimulated rock volume — the connected fracture network that actually exchanges heat. Injectivity index: flow per unit drawdown, L/(s·MPa).

9 · Two-phase pipeline flow
Homogeneous (no-slip) mixture specific volume and density
Mass flux and mixture velocity
Homogeneous-equilibrium momentum equation; the 1/(1−M²) factor is choking
Homogeneous sonic velocity of the mixture
Void fraction (homogeneous, i.e. slip ratio = 1)
Colebrook–White friction factor (Swamee–Jain explicit form used)
Two-phase viscosity (McAdams)
Energy equation with heat loss to ambient
Saturated two-phase state — pressure, temperature and quality are tied together
API RP 14E erosional velocity (C ≈ 100–125)

Definitions. Flashing: boiling driven by a pressure drop rather than by heating — the dominant process in a geothermal gathering line. Homogeneous equilibrium model (HEM): both phases share velocity and temperature; it is a simplified model that neglects phase slip and may mispredict hold-up. Slip: the vapour travelling faster than the liquid, which HEM ignores. Choked flow: the exit reaches the sonic velocity, after which lowering the downstream pressure does not increase the flow. Quality (x): steam mass fraction.

10 · Kalina cycle and NH₃–H₂O mixture properties
Modified Raoult's law — bubble pressure of the mixture
Regular-solution activity coefficients (Ω = −5.2 kJ/mol for NH₃–H₂O)
Wagner vapour-pressure form; τ = 1 − T/Tc, Tc = 405.4 K, Pc = 113.3 bar
Vapour composition in equilibrium with liquid x (dew construction)
Lever rule in the separator and the glide that makes the mixture attractive
Mass-basis mixture enthalpy including the heat of mixing
Isentropic turbine expansion of the rich vapour
Recuperator duty, sized on the hot (lean) stream
First-law and exergy (utilisation) efficiency
Ideal-gas isentropic relation — the limiting case recovered at low pressure

Definitions. Kalina cycle: a Rankine cycle whose working fluid is a zeotropic mixture, so that composition can be changed by partial distillation and the boiling/condensing temperatures glide. Separator: the vessel where the heated mixture splits into ammonia-rich vapour (to the turbine) and ammonia-lean liquid (recuperated, throttled and re-absorbed). Glide: the temperature difference between bubble and dew points at one pressure — 100 K or more here. Zeotropic: a mixture whose components boil at different temperatures, so phase change happens over a range rather than at a single point. Vapour properties use the reference ammonia equation of state (tabulated), liquid enthalpies the same source plus IF97 steam, and the vapour phase is treated as ideally mixed.

11 · Monte-Carlo uncertainty and LCOE distributions
Capital recovery factor
Levelised cost per kWh, with C in USD/kW and cO&M in USD/(kW·yr)
Sampling assumption: multiplicative, truncated normal at ±3σ
Percentiles of the output distribution and the probability of beating the market
Spearman rank correlation — the tornado metric
Coefficient of variation of the cost estimate

Definitions. Monte Carlo: propagating input distributions through a deterministic model to obtain the output distribution. P10/P50/P90: values with a 10 %, 50 % and 90 % chance of not being exceeded — these percentiles describe only the assumed scenario model, not bankability or debt sizing. Tornado diagram: ranked sensitivity, here by rank correlation so it is robust to skewed inputs. Coefficient of variation: dispersion relative to the mean; a high value indicates sensitivity to assumed uncertainties, not an independent bankability test.

Symbols

SymbolMeaningUnit
h, hf, hfg, hgenthalpy: mixture, saturated liquid, latent, saturated vapourkJ/kg
s, sf, sfg, sgentropy (same subscripts)kJ/(kg·K)
xsteam quality / vapour mass fraction–
k, αthermal conductivity, thermal diffusivityW/(m·K), m²/s
Rb, Rgborehole / ground thermal resistancem·K/W
ηt, ηgturbine isentropic, generator efficiency–
ηth, ηuthermal (first-law), utilisation (exergy) efficiency–
CFcapacity factor–
i, nreal discount rate, project life–, yr

Note on properties: the saturated-water/steam core is approximated by a 1 °C saturation table with linear interpolation. The last table row approximates the critical endpoint and is not used for routine interpolation; accuracy is not certified, especially above 350 °C or outside the saturation boundary. Superheated and two-phase non-equilibrium states use engineering approximations. The NH₃–H₂O cycle (tab 10) is the exception: it carries its own vapour–liquid equilibrium model built on the reference ammonia equation of state, a tabulated superheat grid, IF97 steam and regular-solution activity coefficients. Other organic working fluids (tab 4) are still handled through the Carnot-fraction method rather than a full equation of state.

Engineering methods, sources and model limits

RENEWIOSITY prioritizes transparent assumptions. Saturation-table interpolation is screening-grade; near-critical states need full IF97. Borehole geometry, EGS fracture behaviour, ammonia–water cycles and two-phase transport require dedicated validation before design decisions.

API RP 14E erosional velocity is used only as an empirical screening indicator; it is not a generalized geothermal corrosion/erosion acceptance test. No specialist cycle accuracy or bankability claim is made.

1 · Resource assessment

Temperature-at-depth from a conductive geotherm, heat flux, and a volumetric (heat-in-place) estimate of what the reservoir could support. Use this to screen a prospect before any well exists.

Inputs site & reservoir


How to read this

  • A conductive geotherm understates real field temperatures — convective systems are hotter at the same depth, and gradient must be measured in a dedicated (non-flowing) well.
  • Heat-in-place is not a reserve. Recovery factor and conversion efficiency dominate the result; treat the output as an order-of-magnitude screening number.
  • Below ~120 °C, power generation needs a binary plant (tab 4). Above ~180 °C, flash cycles (tab 3) become attractive.

Results —

Temperature and boiling point with depth

Conductive geotherm vs saturation temperature for a hydrostatic column — the crossover is where free boiling would begin

Recoverable energy vs reservoir area

Equivalent continuous electric output over the project life

2 · Wellbore & fluid properties

Hydrostatic pressure, flashing depth, wellhead steam fraction and exergy of the produced fluid, plus an IAPWS‑IF97 saturated-water/steam property lookup.

Well inputs

Reference for exergy; usually ambient.

Steam-table lookup IAPWS‑IF97

Well performance —

Pressure vs depth

Hydrostatic column pressure and saturation pressure at the well temperature — crossing marks flashing

Wellhead steam fraction vs pressure

Adiabatic (isenthalpic) flash of the produced fluid at the wellhead

Saturated water / steam at the reservoir temperature

3 · Flash power plant

Single- and double-flash steam cycles: separator split, isentropic turbine expansion, condenser and cooling-water duty, specific steam consumption and utilisation efficiency.

Resource & plant inputs

Used only for the double-flash case; typically 0.15–0.3.

Results —

Power vs separator pressure

Separation temperature falls with pressure (more steam) but turbine enthalpy drop shrinks — hence an optimum

Net power and exhaust quality vs condensing temperature

Marked point is the design case; quality below 0.88 risks blade erosion

Stage-by-stage state table

4 · Binary / ORC plant

Organic Rankine (or Kalina) cycle matched to a low- to medium-temperature brine. Sizes the net output, the brine cooling range set by pinch, and the heat-exchanger surface implied by an assumed U-value.

Brine & cycle inputs

ηth/ηCarnot: User-specified screening factor; calibrate to measured performance

Model basis

Working-fluid properties are represented through a Carnot-fraction method, not a full equation of state: ηth = f·(1 − Tcd/Tev). Calibrate f against a vendor guarantee or a real plant before using the output for procurement. Air-cooled condensers typically carry 20–25 % parasitics and allow a higher Tcd.

Results —

Net output vs evaporation temperature

Higher Tev raises efficiency but leaves more heat in the brine (pinch-limited)

Efficiency vs evaporation temperature

Practical cycle efficiency against its Carnot ceiling at the same sink temperature

5 · Borehole heat exchanger field (GSHP)

Preliminary single-borehole line-source screening estimate; excludes borefield interference and time-varying loads. A layout-specific g-function calculation and site thermal response testing are necessary for final design.

Building loads


Ground & borehole

Field sizing —

Boreholes required vs ground conductivity

Thermal conductivity is the single most influential ground parameter — and the one most worth measuring with a TRT

Entering fluid temperature drift

Peak EFT each year for the designed field, against the design limits

Design summary

6 · Direct use, district heating & pipelines

Flow rate, velocity, Reynolds number, Colebrook friction factor, pumping power and buried-pipe heat loss for a hot-water network delivering geothermal heat.

Network inputs


Insulation & burial

Results —

Pumping power vs pipe size

Pumping power falls steeply with diameter while pipe cost rises — the classic optimum-diameter trade-off

Heat loss vs insulation thickness

Diminishing returns: beyond ~2× pipe radius the soil resistance dominates

7 · Project economics & LCOE

Capital breakdown dominated by drilling, levelised cost, NPV/IRR and a discounted cash-flow profile. All costs in constant (real) money — use a real discount rate.

Plant & wells


Used for revenue, NPV, IRR and payback.

Economics —

Discounted cumulative cash flow

Crossing zero is the discounted payback year

LCOE sensitivity

LCOE against the real discount rate — the single most sensitive financial input

Capital cost breakdown

8 · EGS hydraulics and stimulation

Enhanced Geothermal Systems make their own permeability: inject cold water above the least principal stress, shear and open natural fractures, then circulate. This tab couples the in-situ stress state, the injection pressure you must hold, the injectivity you can expect with and without stimulation, thermoelastic stress change during cold injection, and thermal breakthrough at the production well.

Inputs reservoir & well

0.3 extensional, 0.6–0.8 strike-slip.
Used for the thermoelastic term only.


How to read this

  • Breakdown pressure sets the ceiling. If your required bottom-hole injection pressure exceeds it, the rock parts — that is the point of stimulation, but it also means you cannot simply raise pressure to raise flow.
  • Thermoelastic stress is the quiet workhorse of EGS: cooling the rock by ΔT reduces the horizontal stress by EαΔT/(1−ν). Once that reduction approaches half the differential stress, pre-existing fractures shear — permeability grows without proppant.
  • Injectivity is dominated by the fracture, not the matrix. Matrix permeability below ~1 mD cannot accept commercial rates at sane pressures.
  • Thermal breakthrough is the clock on the project: cold water returns once the swept rock volume is depleted of heat.

Results —

Injection pressure vs flow rate

Bottom-hole pressure needed, against the breakdown ceiling and the wellhead pressure you would pump at

Thermoelastic stress change with cooling

Horizontal-stress reduction EαΔT/(1−ν) against the shearing threshold — the crossover is the ΔT that self-props the reservoir

Injectivity vs permeability

Matrix-only well against the same well with the stimulated fracture set

Produced temperature and thermal breakthrough

Doublet response for three swept volumes; the knee is the end of the high-grade heat

Stress state and pressure envelope

9 · Two-phase pipeline and gathering flow

From the wellhead to the plant the geothermal fluid flashes as pressure falls: quality rises, volume flow grows by orders of magnitude, and the pressure gradient becomes a fight between friction, gravity and acceleration. This is a marching (step-wise) integration of the homogeneous two-phase model with heat loss to ambient.

Inputs wellhead & line

Steam mass fraction. 0 = compressed liquid.
Positive = the line rises toward the plant.
Bare steel ≈ 10–20, insulated ≈ 1–3.
API RP 14E (customary C units; SI-converted result), Ve = C/√ρ.

How to read this

  • Two-phase pressure gradient is not the sum of single-phase values: the mixture density collapses as quality rises, so friction accelerates the flash, which lowers pressure, which raises quality. The coupling is why the profiles bend.
  • Heat loss matters most on long, small-diameter lines; on a DN250 line at 30 kg/s it is a couple of percent of the enthalpy, but it can still condense steam and drop the arrival quality sharply.
  • Compare the mixture velocity with the erosional velocity C/√ρ and with the homogeneous sonic velocity: a wellhead near sonic velocity is choked and no downstream valve will raise the flow.
  • Homogeneous model (no slip): it neglects phase slip and may over- or under-predict the pressure drop depending on flow regime. Do not size piping without a validated multiphase-flow method.

Results —

Pressure profile

Flowing pressure along the line; the gradient steepens as quality rises and the mixture lightens

Quality profile

Steam mass fraction along the line

Temperature profile

Mixture temperature against saturation temperature; the gap widens as heat is lost

Velocity and erosion limit

Mixture velocity against the API RP 14E (customary C units; SI-converted result) erosional velocity

Pressure budget and regime assessment

10 · Kalina cycle (NH₃–H₂O)

A real mixture property model: ammonia–water vapour–liquid equilibrium from the reference ammonia equation of state, IF97 steam and regular-solution activity coefficients, with an energy-consistent separator, recuperator, turbine and condenser. Because the working fluid boils and condenses over a glide rather than at one temperature, the heating curve can be matched to the cooling brine far better than a pure fluid can.

Inputs heat source


How to read this

  • Phi is the design variable. Raising it lifts the separator temperature (better brine match, higher efficiency) but shrinks the expansion ratio and eventually the separator cannot make vapour at all. The net-power curve therefore has a maximum — find it on the second chart before fixing the pump rating.
  • Glide is the temperature difference between bubble and dew at the same pressure. It is 100 K or more here; that is the entire reason a mixture beats a pure fluid on a cooling brine.
  • Exhaust quality below ~0.88 means droplet erosion; above 1.0 the turbine is dry and the condenser has spare surface.
  • The lean liquid leaving the separator is throttled back and re-absorbed, which is why the condenser duty exceeds the turbine exhaust enthalpy — a Kalina condenser is an absorber.

Results —

Equilibrium T–xy at Phi

Bubble and dew lines with the separator state, the feed and the lean/rich streams

Net power vs Phi

Sweep over the high pressure at the current separator vapour fraction — the peak is the design point

Heat-exchanger composite curves

Brine giving up heat against the mixture heating curve; the closest approach is the pinch

Net power vs ammonia content

Ammonia-rich mixtures glide more but separate differently — the composition is a real design choice

State points

11 · Monte-Carlo LCOE risk

Every number in the economics tab is a guess. This tab turns one guess per input into a distribution: sample the uncertain inputs, run the levelised-cost equation for every sample, and read the answer as a probability rather than a point. Outputs are P10/P50/P90 LCOE quantiles and the fraction of simulated cases below a reference price, conditional on assumed distributions, not objective forecasts.

Inputs distributions

Absolute percentage points.
Same seed, same answer — results are reproducible.

How to read this

  • A single LCOE number hides the risk that decides the investment. Use P50 and P90 as descriptive percentiles of the assumed sampling model, not investment or debt-sizing forecasts.
  • The tornado is a rank correlation, not a regression slope: it is robust to the skewed cost distributions you will actually face.
  • LCOE is roughly linear in capital cost and discount rate but strongly non-linear in capacity factor — a 20 % CF miss hurts more than a 20 % capex overrun at these rates.
  • Correlations between inputs (e.g. capex and schedule overrun) are deliberately not modelled; adding them widens the distribution, so treat these bands as a floor on uncertainty.

Results —

LCOE distribution

Histogram of the sampled LCOE with P10 / P50 / P90

Probability of being cheaper than the market

Cumulative distribution against the market price

Tornado: what actually drives the cost

Rank correlation of each input with LCOE

LCOE against capital cost

Every sample plotted; the vertical band is the P10–P90 range

Percentile table and input ranking